KOOLTHERM K17 PDF

Call and press " 2 " to speak with Technical services, email technical kingspaninsulation. Please contact Kingspan Insulation Technical Services on or email technical kingspaninsulation. Product Thickness inc. Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife through the insulation and scoring the back of the plasterboard itself, then snapping the board over a straight edge and then cutting the facing on the other side. Ensure accurate trimming to achieve close-butting joints and continuity of insulation.

Author:Shakami Dushakar
Country:Zimbabwe
Language:English (Spanish)
Genre:Environment
Published (Last):22 October 2016
Pages:278
PDF File Size:10.21 Mb
ePub File Size:9.10 Mb
ISBN:307-3-60420-191-5
Downloads:70388
Price:Free* [*Free Regsitration Required]
Uploader:Gardajar



Click on the specific application types below to view their System R-values. Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Ensure accurate trimming to achieve close-butting joints and continuity of insulation. Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs.

We're ready to help. We use cookies on our website www. To find out more about the cookies we use, or to change your cookie preferences i. Please click "Accept and close" to accept the use of cookies on our website. Kooltherm K17 Insulated Plasterboard. CodeMark certified 3-in-1 insulation, dry-lining and vapour control Available in a range of other selected lining materials Group 1 fire classification.

Contact Us. Download Product Brochure. Pricing and Where to Buy. Request Technical Support. Register Project Specification. Minimum order quantities apply. Product Thickness 35, 40, 50, 60, 70, 80, 90 mm Other thicknesses available upon enquiry. Please contact us for more information. The contribution of the product Total R-values depends on installation and environmental conditions. Product R-values. Product Thickness inc. System R-values Click on the specific application types below to view their System R-values.

System R-value. Block Wall mm View System R-value. Handling, Storage, and Cutting. Boards should be stored inside a building. If, however, temporary outdoor storage cannot be avoided then the boards should be stacked flat on a level base, clear of the ground, and completely protected from inclement weather through use of a polythene sheet or weatherproof tarpaulin.

Boards that have been allowed to get wet should not be used. Resistance to Solvents The insulation core is resistant to short-term contact with petrol and with most dilute acids, alkalis and mineral oils.

However, it is recommended that any spills be cleaned off fully before the boards are installed. Ensure that safe methods of cleaning are used, as recommended by suppliers of the spilt liquid. The insulation core is not resistant to some solvent-based adhesive systems, particularly those containing methyl ethyl ketone.

Adhesives containing such solvents should not be used in association with this product. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. Cutting Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side.

Please note that the reflective surfaces on this product are designed to enhance their thermal performance. As such, the will reflect light as well as heat, including ultraviolet light. Therefore, if these boards are being installed during bright or sunny weather, it is advisable to wear UV protective sunglasses or goggles and if the skin is exposed for a significant period of time, protect bare skin with a UV block sun cream.

Foil facings are conductive to electricity - avoid contact with un-insulated electrical cables and fittings. Dry Wall Plasterboard View Instructions. Kingspan Kooltherm K17 Insulated Plasterboard can be applied utilising a variety of traditional or modern dry-lining techniques, to dry and structurally sound walls. These include the construction adhesive bonding method. The particular system employed will depend on the construction or design of the wall to which Kingspan Kooltherm K17 Insulated Plasterboard is to be fixed.

If an acceptable adhesive bond cannot be achieved due to the wall surface, consideration should be given to a mechanically fixed option. Ensure that the wall surface to be bonded to is free from oil, grease, paint, release agent, or any contaminate that may affect the bond of the adhesive to the wall.

Gun apply a continuous blob of construction adhesive around perimeter wall and ceiling junctions, and around any openings, such as windows and doors, in order to provide a seal. Ensure that the blobs adjacent to a board joint are approximately 25 mm in from the edge to avoid bridging the joint.

Tap the board back firmly using a straightedge, ensuring that the vertical edge is plumb. Continue dry lining in the same manner. Mechanical fixings are recommended to complement the adhesive bond. Apply 2 per board after the adhesive has set, positioned 15 mm in from the board edge and at mid height with a nominal 25 mm embedment into the wall.

Refer to fixing manufacturer instructions for more information. It is recommended that mechanical fixings are positioned in the tapered edge of the boards so that they are covered when the board is finished, e. Do you need help and advice on your project? Send Us An Enquiry. Kingspan Insulation Asia We're ready to help.

HIKA LEO BROUWER PDF

Kooltherm K17 Insulated Plasterboard

Click on the specific application types below to view their System R-values. Cutting should be carried out either by using a fine toothed saw, or by scoring with a sharp knife, snapping the board over a straight edge and then cutting the facing on the other side. Ensure accurate trimming to achieve close-butting joints and continuity of insulation. Our teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs. We're ready to help. We use cookies on our website www.

KUKA SYSTEM SOFTWARE 5.5 FILETYPE PDF

INSULATION

Kingspan Kooltherm K17 Insulated Plasterboard is a super high performance, fibre-free rigid thermoset, closed cell phenolic insulation, sandwiched between a front facing of tapered edge gypsum based plasterboard, and a reverse tissue based facing autohesively bonded to the insulation core during manufacture. Boards that have been allowed to get wet should not be used. The insulation core is resistant to short—term contact with petrol and with most dilute acids, alkalis and mineral oils. However, it is recommended that any spills be cleaned off fully before the boards are installed.

HP 8552B PDF

62.5mm Kooltherm K17 - Kingspan - Phenolic Insulation with Plasterboard - pack of 12

Thermal conductivity insulant thickness 0. K mm 0. K 25—44 mm 0. Board size 1. Our expert technical services team can provide you with a U-value. We offer a dedicated retrofit service to help with this. Highest performing insulation manufactured in Ireland.

THE NORMAL CHRISTIAN LIFE WATCHMAN NEE PDF

Kingspan Kooltherm K17 Insulated Plasterboard

.

Related Articles